For the 2026-2027 winter, the best approach in Brussels is to heat your radiators with cooler water and check that they are large enough to do so. Energy prices rose sharply this autumn and the regional Renolution grants have been discontinued: every degree saved on the water temperature counts. But be aware that a radiator chosen based on its catalogue power may only deliver half that power at low temperatures. This guide helps you assess your needs before the severe cold sets in.
Published on 21 October 2026 — price and regulatory data verified as of this date.
According to Test-Achats (5 October 2026), fixed contracts rose again in October: around 9.05 c€/kWh for gas in Wallonia and 8.97 c€/kWh in Flanders, around 21.3 c€/kWh for electricity. Compared to March 2026 prices, this represents nearly €670 more per year for a household consuming 17,000 kWh of gas. Social tariffs are following suit: the CREG raised social gas tariffs by 11.4% for the last quarter of 2026.
Two practical consequences for your radiators:
Manufacturers express a radiator's power according to the European standard EN 442, with water at 75 °C leaving, 65 °C returning, and a room at 20 °C ("75/65/20" rating).
Example with two horizontal radiators from our range, 60 cm high and 100 cm long:
| Water temperature | T22 600 x 1000 | T33 600 x 1000 | Typical use |
|---|---|---|---|
| 75/65 °C (catalogue power) | 1,732 W | 2,389 W | Old boiler set "full blast" |
| 55/45 °C | ≈ 890 W | ≈ 1,230 W | Well-adjusted condensing boiler |
| 45/35 °C | ≈ 525 W | ≈ 725 W | Heat pump |
Calculated using the standard EN 442 conversion formula (exponent 1.3), based on the nominal powers from our product sheets. Indicative values, rounded.
A properly insulated 12 m² bedroom requires around 850 W (70 W/m²). A T22 600 x 1000 is sufficient with a condensing boiler set to 55 °C. With a heat pump at 45 °C, it only provides 525 W: you must switch to a T33 140 cm long (around 1,000 W at 45 °C), or add a second radiator. The right sizing is therefore done room by room, at the actual temperature of your installation.
| Model | Design | When to choose it |
|---|---|---|
| T22 | 2 panels, 2 rows of fins | The standard: bedrooms, living rooms with gas boiler |
| T33 | 3 panels, 3 rows of fins: around 38% more power at the same dimensions | Low temperature, heat pump, poorly insulated room, wall too short for a T22 |
| Vertical | Tall, narrow | Little free wall space under windows, contemporary living rooms |
| Towel rail | Horizontal tubes, hot water or electric | Bathroom: heating and drying clothes |
| Electric | Independent of the heating circuit | Supplementary heating, bathroom, room without piping |
The detail that simplifies a renovation: our horizontal radiators are available in an 8-connection version (4 on the sides, 4 from the bottom). You can replace an old radiator without moving the pipes, regardless of where they come out of the wall or floor. See our T22/T33 8-connection and our 6-connection versions.
Not necessarily all of them. In most Brussels homes, only one or two rooms are undersized for 45 °C water: often the living room, or a room under the roof. The best method:
You will save on gas starting this winter, and you will prepare for the switch to the heat pump without redoing everything.
The radiator is no longer hidden. Vertical models in matte black or white, with a flat surface, stand out as a decorative element, and matching fittings (white, black, chrome) finish the job. See ours: the vertical Evo (1800 x 600 mm, 3,460 W catalogue power), the Plano, and the towel rails Linteo, Sueno and Farko, including 700 W electric versions for bathrooms without a hot water circuit. Also think about our connection sets in the same shade as the radiator.
One sized for water at around 45 °C, which often means choosing a T33 or a larger radiator than the old one. A radiator only delivers around 30% of its catalogue power at 45 °C: the calculation must be done at this temperature.
A radiator's power depends directly on the water temperature. At 55 °C, it delivers about half its catalogue power. If a room remains cold, it is because this radiator is too small for this temperature: it is the one that needs to be replaced, not the entire installation.
As main heating, rarely: the electric kWh costs around 2.4 times more than the gas kWh at October 2026 rates. As supplementary heating, in a bathroom or a room rarely used, it remains a simple and inexpensive solution to install.
No more Renolution regional grant for invoices dated 2025 or later. The 6% VAT remains applicable in the renovation of a home over 10 years old, and some municipalities maintain their own aid.
The T22 has two panels and two rows of fins, the T33 has three of each. At the same dimensions, the T33 heats around 38% more, making it the reference choice for low temperature.
Send us the surface area of each room, the type of boiler or heat pump, and a photo of your current radiators with their dimensions. We will indicate which ones are sufficient and which ones are better replaced, and we will offer you a quote for supply or supply + installation.